Estudio del análisis de respuesta en frecuencia como herramienta de diagnóstico y evaluación de desplazamientos y deformaciones internas en transformadores de potencia

dc.contributor.author Alvarez Bermúdez, Fabio de Jesús spa
dc.contributor.author Díaz Jiménez, Sergio Ricardo spa
dc.creator.degree Ingeniero Electricista spa
dc.date.accessioned 2013-02-21T20:46:29Z
dc.date.accessioned 2021-11-02T23:30:35Z
dc.date.available 2013-02-21T20:46:29Z
dc.date.available 2021-11-02T23:30:35Z
dc.date.issued 2012
dc.description.abstract En el presente documento se muestra el estudio del método conocido con el nombre de Análisis del Barrido de la Respuesta en Frecuencia, como herramienta de diagnóstico y evaluación de desplazamientos y deformaciones internas en transformadores de potencia; para dar comienzo al documento se presenta una breve introducción mediante la cual el lector podrá darse una explicación o idea general acerca del método y contenido del texto. Seguidamente se exponen las razones por las cuales se presenta la motivación para dar inicio a al estudio aquí mostrado, posteriormente, con el único fin de agregar claridad al trabajo expuesto y organizar las ideas generales que se puedan tener del mismo, llegaremos a los antecedentes y estado del arte del Análisis del Barrido de la Respuesta en Frecuencia. Proporcionando un esquema básico, se ofrece de forma general el fundamento físico de los transformadores eléctricos mediante temas como: especificaciones técnicas, diseños, fabricación, ensayos y pruebas, “comisionamiento” o puesta en servicio de los equipos objeto del presente estudio. De igual modo y debido al uso, abuso o a razón de contingencias presentadas en el sistema eléctrico también, los transformadores ocasionalmente deben ser intervenidos para realizar algún tipo de mantenimiento, para esto, el actual documento se pueden encontrar temas como: reparación, reconstrucción, mantenimiento, análisis de fallas detectadas, herramientas de diagnóstico para la evaluación de la calidad del sistema de aislamientos (papel/aceite), accesorios y demás elementos presentes en el transformador, con el fin de brindar al lector instrumentos útiles y precisos no solo para captar su atención en este documento, sino también para impulsarlo a lograr en la practica el mejor desempeño, y reducir la posibilidad de parada abrupta de los transformadores. Finalmente, se expone y se describe el funcionamiento del método Análisis del Barrido de la Respuesta en Frecuencia, su importancia, características, forma de evaluación, interpretación, fallas detectadas mediante el método, análisis y conclusiones con respecto a las graficas mostradas donde se describen los cambios ocurridos al interior del transformador ante distintos tipos de falla o alteración ocurrida de acuerdo a la información obtenida después del estudio bibliográfico y la aplicación real llevada a cabo sobre transformadores de potencia en la planta de fabricación de transformadores Magnetrón S.A., ubicada en el municipio de Pereira. spa
dc.description.abstractenglish A study using the Sweep Frequency Response Analysis Method (SFRA) for power transformer diagnostics is presented. This paper shows the study of the method known as Sweep Frequency Response Analysis Method as a tool for diagnosis and evaluation of internal displacements and deformations in power transformers, first, the paper provides a brief introduction in which the reader can get an explanation or general idea about the method and content of the text. Then sets out the reasons or motivation of why is presented the study shown here, for the sole purpose of adding clarity to the work exhibited and organize the general ideas that can be the same, we arrive at the background and state of the art of Sweep Frequency Response Analysis. Providing a basic framework, provides an overview of the physical basis of electrical transformers by topics such as technical specifications, design, manufacture, testing and testing, "commissioning" or putting into service of equipment covered by this study. In the same way and due to the use, abuse or because of contingencies presented in the electrical system also occasionally transformers must be operated to perform any maintenance to this, the present document may be found topics such as repair, reconstruction, maintenance, analysis of faults detected, diagnostic tools for assessing the quality of the insulation (paper / oil), accessories and other elements present in the transformer, to provide the reader with useful and necessary not only to capture their attention in this document, but also to promote it in practice to achieve the best performance, and reduce the possibility of abrupt stop of the transformers. Finally, it exposes and describes the operation of the method of frequency response analysis, its importance, characteristics, method of evaluation, interpretation, faults detected by the method, analysis and conclusions with respect to the graphs shown which describes the changes inside the transformer to different types of failure or disruption occurred according to information obtained after literature review and the actual implementation carried out on power transformers in the transformer manufacturing plant called Magnetron SA, located in Pereira, Colombia. eng
dc.format application/pdf spa
dc.identifier.local T621.314 A473;6310000087712 F1897 spa
dc.identifier.uri https://hdl.handle.net/11059/2909
dc.language.iso spa spa
dc.publisher Pereira : Universidad Tecnológica de Pereira spa
dc.publisher.department Facultad de Ingenierías Eléctrica, Electrónica, Física y Ciencias de la Computación spa
dc.publisher.program Ingeniería Eléctrica spa
dc.rights Attribution-NonCommercial-NoDerivatives 4.0 International *
dc.rights EL AUTOR, manifiesta que la obra objeto de la presente autorización es original y la realizó sin violar o usurpar derechos de autor de terceros, por lo tanto la obra es de exclusiva autoría y tiene la titularidad sobre la misma. PARÁGRAFO: En caso de presentarse cualquier reclamación o acción por parte de un tercero en cuanto a los derechos de autor sobre la obra en cuestión, EL AUTOR, asumirá toda la responsabilidad, y saldrá en defensa de los derechos aquí autorizados; para todos los efectos la universidad actúa como un tercero de buena fe. EL AUTOR, autoriza a LA UNIVERSIDAD TECNOLOGICA DE PEREIRA, para que en los términos establecidos en la Ley 23 de 1982, Ley 44 de 1993, Decisión andina 351 de 1993, Decreto 460 de 1995 y demás normas generales sobre la materia, utilice y use la obra objeto de la presente autorización. spa
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/ *
dc.subject Análisis de circuitos eléctricos spa
dc.subject Sistemas de control spa
dc.subject Sistemas eléctricos spa
dc.subject Transformadores de frecuencia spa
dc.subject Transformadores eléctricos spa
dc.subject Transmisión de potencia spa
dc.title Estudio del análisis de respuesta en frecuencia como herramienta de diagnóstico y evaluación de desplazamientos y deformaciones internas en transformadores de potencia spa
dc.type bachelorThesis spa
dc.type.hasVersion acceptedVersion spa
Archivos
Paquete original
Mostrando 1 - 1 de 1
Imagen en miniatura
Nombre:
621314A473.pdf
Tamaño:
3.57 MB
Formato:
Adobe Portable Document Format
Descripción:
Documento Principal
Paquete de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
834 B
Formato:
Plain Text
Descripción: